<TITLE>
TITLE: System panic from netrain_switch() when NetRAIN interface switches
Copyright (c) Hewlett-Packard Company 2005. All rights reserved.
PRODUCT: HP Tru64 UNIX [R] V5.1B-3
SOURCE: Hewlett-Packard Company
ECO INFORMATION:
ECO Name: T64KIT0026391-V51BB26-E-20050908
ECO Kit Approximate Size: 3.47MB
Kit Applies To: HP Tru64 UNIX V5.1B-3 PK5 (BL26)
ECO Kit CHECKSUMS:
/usr/bin/sum results:
24885 3550
/usr/bin/cksum results:
2460360644 3635200
MD5 results:
1167fc874b0abd87eb98781691326735
SHA1 results:
043ed3065d0b8b95d7d7f612e7639d61f0f8f0e4
ECO KIT SUMMARY:
A dupatch-based, Early Release Patch kit exists for HP Tru64 UNIX V5.1B-3
that contains solutions to the following problem(s):
On HP Tru64 UNIX 5.1B-3 a system panic can panic can result when the
Redundant Array of Independent Network Adapters (NetRAIN) performs an
interface switch.
The Patch Kit Installation Instructions and the Patch Summary and Release
Notes documents provide patch kit installation and removal instructions
and a summary of each patch. Please read these documents prior to
installing patches on your system.
The patches in this ERP kit will also be available in the next mainstream
patch kit - HP Tru64 UNIX V5.1B-4.
INSTALLATION NOTES:
1) Install this kit with the dupatch utility that is included in the patch
kit. You may need to baseline your system if you have manually changed
system files on your system. The dupatch utility provides the baselining
capability.
2) The patch in this ERP kit does not have any file intersections with any
other ERP available at this time for this product version.
3) This ERP kit will NOT install over any Customer Specific Patches (CSPs)
which have file intersections with this ERP kit. Contact your normal
Service Provider for assistance if the installation of this ERP kit is
blocked by any of your installed CSPs.
INSTALLATION PREREQUISITES:
You must have installed HP Tru64 UNIX V5.1B-3 PK5 (BL26) prior to
installing this Early Release Patch Kit.
SUPERSEDE INFORMATION:
None
KNOWN PROBLEMS WITH THE PATCH KIT:
None.
RELEASE NOTES FOR T64KIT0026391-V51BB26-E-20050908:
Release Notes
This document summarizes the contents and special instructions for the
Tru64 UNIX V5.1B patches contained in this kit.
For information about installing or removing patches, baselining,
and general patch management, see the Patch Kit Installation
Instructions document.
1 Release Notes
This Early Release Patch Kit Distribution contains:
- fixes that resolve the problem(s) reported in:
o 18858 18895
* for Tru64 UNIX V5.1B T64V51BB26AS0005-20050502.tar (BL26)
The patches in this kit are being released early for general customer use.
Refer to the Release Notes for a summary of each patch and installation
prerequisites.
Patches in this kit are installed by running dupatch from the directory
in which the kit was untarred. For example, as root on the target system:
> mkdir -p /tmp/CSPkit1
> cd /tmp/CSPkit1
> <copy the kit to /tmp/CSPkit1>
> tar -xpvf DUV40D13-C0044900-1285-20000328.tar
> cd patch_kit
> ./dupatch
2 Special Instructions
There are no special instructions for Tru64 UNIX V5.1B Patch C1273.00
3 Summary of CSPatches contained in this kit
Tru64 UNIX V5.1B
PatchId Summary Of Fix
----------------------------------------
C1273.00 Fix for netrain_switch: sprintf panic
4 Additional information from Engineering
None
5 Affected system files
This patch delivers the following files:
Tru64 UNIX V5.1B
Patch C1273.00
./sys/BINARY/netrain.mod
CHECKSUM: 51154 345
SUBSET: OSFBIN540
[R] UNIX is a registered trademark in the United States and other countries
licensed exclusively through X/Open Company Limited.
Copyright Hewlett-Packard Company 2005. All Rights reserved.
This software is proprietary to and embodies the confidential technology
of Hewlett-Packard Company. Possession, use, or copying of this
software and media is authorized only pursuant to a valid written license
from Hewlett-Packard or an authorized sublicensor.
This ECO has not been through an exhaustive field test process.
Due to the experimental stage of this ECO/workaround, Hewlett-Packard
makes no representations regarding its use or performance. The
customer shall have the sole responsibility for adequate protection