<TITLE>
TITLE: HP Tru64 UNIX - v 5.1B-3 Potential AdvFS Hangs
Copyright (c) Hewlett-Packard Company 2006. All rights reserved.
PRODUCT: HP Tru64 UNIX [R] V5.1B-3
SOURCE: Hewlett-Packard Company
ECO INFORMATION:
ECO Name: T64KIT1000508-V51BB26-E-20060406
ECO Kit Approximate Size: 3.66MB
Kit Applies To: HP Tru64 UNIX V5.1B-3 PK5 (BL26)
ECO Kit CHECKSUMS:
/usr/bin/sum results:
62550 3750
/usr/bin/cksum results:
813880652 3840000
MD5 results:
f060a0a09a629e675cc2f4b6ffb0db90
SHA1 results:
8c490aba9ba1727fa6ffb56206b5e1f2a66c1ce7
ECO KIT SUMMARY:
A dupatch-based, Early Release Patch kit exists for HP Tru64 UNIX V5.1B-3
that contains solutions to the following problem(s):
This ERP kit fixes four potential AdvFS hangs.
Two hangs have been fixed previously in kit
T64KIT0025601-V51BB26-E-20050513. This kit combines the previous fixes with
fixes for two additional 5.1B-3 AdvFS hangs.
The Patch Kit Installation Instructions and the Patch Summary and Release
Notes documents provide patch kit installation and removal instructions
and a summary of each patch. Please read these documents prior to
installing patches on your system.
The patches in this ERP kit will also be available in the next mainstream
patch kit - HP Tru64 UNIX V5.1B-4.
INSTALLATION NOTES:
1) Install this kit with the dupatch utility that is included in the patch
kit. You may need to baseline your system if you have manually changed
system files on your system. The dupatch utility provides the baselining
capability.
2) This ERP kit will NOT install over any Customer Specific Patches (CSPs)
which have file intersections with this ERP kit. Contact your normal
Service Provider for assistance if the installation of this ERP kit is
blocked by any of your installed CSPs.
INSTALLATION PREREQUISITES:
You must have installed HP Tru64 UNIX V5.1B-3 PK5 (BL26) prior to
installing this Early Release Patch Kit.
SUPERSEDE INFORMATION:
Kit T64KIT1000508-V51BB26-E-20060406 replaces
T64KIT0025601-V51BB26-E-20050513
KNOWN PROBLEMS WITH THE PATCH KIT:
None.
RELEASE NOTES FOR T64KIT1000508-V51BB26-E-20060406:
Release Notes
This document summarizes the contents and special instructions for the
Tru64 UNIX V5.1B patches contained in this kit.
For information about installing or removing patches, baselining,
and general patch management, see the Patch Kit Installation
Instructions document.
1 Release Notes
This Early Release Patch Kit Distribution contains:
- fixes that resolve the problem(s) reported in:
o 18853 19141 19447 19502 19517 9217 QXCM1000243441 QXCM1000301982 QXCM1000302579 QXCM1000320735 QXCM1000328000
* for Tru64 UNIX V5.1B T64V51BB26AS0005-20050502.tar (BL26)
This kit includes a patch which requires system reboot.
The patches in this kit are being released early for general customer use.
Refer to the Release Notes for a summary of each patch and installation
prerequisites.
Patches in this kit are installed by running dupatch from the directory
in which the kit was untarred. For example, as root on the target system:
> mkdir -p /tmp/CSPkit1
> cd /tmp/CSPkit1
> <copy the kit to /tmp/CSPkit1>
> tar -xpvf DUV40D13-C0044900-1285-20000328.tar
> cd patch_kit
> ./dupatch
2 Special Instructions
SPECIAL INSTRUCTIONS for Tru64 UNIX V5.1B Patch C1608.00
3 Summary of CSPatches contained in this kit
Tru64 UNIX V5.1B
PatchId Summary Of Fix
----------------------------------------
C1608.00 Fix AdvFS hangs
4 Additional information from Engineering
None
5 Affected system files
This patch delivers the following files:
Tru64 UNIX V5.1B
Patch C1608.00
./sys/BINARY/advfs.mod
CHECKSUM: 00541 1423
SUBSET: OSFADVFSBIN540
./usr/sys/kern/lockinfo.c
CHECKSUM: 54661 109
SUBSET: OSFBINCOM540
[R] UNIX is a registered trademark in the United States and other countries
licensed exclusively through X/Open Company Limited.
Copyright Hewlett-Packard Company 2006. All Rights reserved.
This software is proprietary to and embodies the confidential technology
of Hewlett-Packard Company. Possession, use, or copying of this
software and media is authorized only pursuant to a valid written license
from Hewlett-Packard or an authorized sublicensor.
This ECO has not been through an exhaustive field test process.
Due to the experimental stage of this ECO/workaround, Hewlett-Packard
makes no representations regarding its use or performance. The
customer shall have the sole responsibility for adequate protection
and back-up data used in conjunction with this ECO/workaround.
|