<TITLE>
TITLE: ERP to fix Tru64 UNIX 5.1B-2/PK4 Tape Handling and Other drd Problems.
Copyright (c) Hewlett-Packard Company 2005. All rights reserved.
PRODUCT: HP TruCluster Server [R] V5.1B-2
SOURCE: Hewlett-Packard Company
ECO INFORMATION:
ECO Name: TCRKIT0024683-V51BB25-E-20050116
ECO Kit Approximate Size: 3.87MB
Kit Applies To: HP TruCluster Server V5.1B-2 PK4 (BL25)
ECO Kit CHECKSUMS:
/usr/bin/sum results:
23574 3960
/usr/bin/cksum results:
2059402137 4055040
MD5 results:
8da5f1298f7f6333db26ba01d018e452
SHA1 results:
7b50e0fdd9dade8ff96a9cf50d01dbd2e0bfa3f1
ECO KIT SUMMARY:
A dupatch-based, Early Release Patch kit exists for HP TruCluster Server V5.1B-2
that contains solutions to the following problem(s):
This Early Release Patch (ERP) fixes several tape-related and other drd
problems found in Tru64 UNIX 5.1B-2/PK4:
1. On deleting a tape device, the ref counts for the device were found to
be incorrect. These incorrect ref counts prevented the device from being
deleted properly.
2. The DRD_KGS_WAIT_TRANS_DONE flag was left set after the transaction was
done. This is a minor problem that could have been caused due to the
problem with the ref counts.
3. A drd ref count is left on when a cluster member loses access to a tape
and then regains it. This could prevent a customer from being able to
delete the tape when the cluster regains from the transition.
4. On certain types of media errors, a tape device could be left in an
unusable state. The device will always return "busy" even though no
transaction is in progress on that device.
5. When an upgrade is done to TCR 5.1B-2/PK4, the cluster could lose
access to backplain RAID devices (e.g., KZPAC, KZPCC, etc).
6. A kernel memory fault panic experienced when no local devt is available
for a device that is locally accessible.
7. A problem experienced when all paths to a disk are lost and a persistent
reservation (i.e., barrier) is in progress.
8. A deadlock situation in open/close when all paths to a disk are lost.
9. A deadlock problem experienced when local connectivity is regained when
an open is in progress.
The Patch Kit Installation Instructions and the Patch Summary and Release
Notes documents provide patch kit installation and removal instructions
and a summary of each patch. Please read these documents prior to
installing patches on your system.
The patches in this ERP kit will also be available in the next mainstream
patch kit - HP TruCluster Server V5.1B-3.
INSTALLATION NOTES:
1) Install this kit with the dupatch utility that is included in the patch
kit. You may need to baseline your system if you have manually changed
system files on your system. The dupatch utility provides the baselining
capability.
2) The patch in this ERP kit does not have any file intersections with any
other ERP available at this time for this product version.
3) This ERP kit will NOT install over any Customer Specific Patches (CSPs)
which have file intersections with this ERP kit. Contact your normal
Service Provider for assistance if the installation of this ERP kit is
blocked by any of your installed CSPs.
INSTALLATION PREREQUISITES:
You must have installed HP TruCluster Server V5.1B-2 PK4 (BL25) prior to
installing this Early Release Patch Kit.
SUPERSEDE INFORMATION:
This ERP Kit replaces (installs over) ERP Kit
TCRKIT0023955-V51BB25-E-20041017.
KNOWN PROBLEMS WITH THE PATCH KIT:
None.
RELEASE NOTES FOR TCRKIT0024683-V51BB25-E-20050116:
Release Notes
This document summarizes the contents and special instructions for the
TruCluster Server V5.1B patches contained in this kit.
For information about installing or removing patches, baselining,
and general patch management, see the Patch Kit Installation
Instructions document.
1 Release Notes
This Early Release Patch Kit Distribution contains:
- fixes that resolve the problem(s) reported in:
o 98119 98214 98227 98352 98436 98546 DE_G09879 DE_G10017 QXCM1000188587 QXCM1000189143 QXCM1000192123 QXCM1000200843 QXCM1000206447 QXCM1000210772 QXCM1000213196 STL929634
* for TruCluster Server V5.1B T64V51BB25AS0004-20040616.tar (BL25)
This kit includes a patch which requires system reboot.
The patches in this kit are being released early for general customer use.
Refer to the Release Notes for a summary of each patch and installation
prerequisites.
Patches in this kit are installed by running dupatch from the directory
in which the kit was untarred. For example, as root on the target system:
> mkdir -p /tmp/CSPkit1
> cd /tmp/CSPkit1
> <copy the kit to /tmp/CSPkit1>
> tar -xpvf DUV40D13-C0044900-1285-20000328.tar
> cd patch_kit
> ./dupatch
2 Special Instructions
There are no special instructions for TruCluster Server V5.1B Patch C227.02
3 Summary of CSPatches contained in this kit
TruCluster Server V5.1B
PatchId Summary Of Fix
----------------------------------------
C227.02 This patch fixes tape problems in DRD
4 Additional information from Engineering
None
5 Affected system files
This patch delivers the following files:
TruCluster Server V5.1B
Patch C227.02
./usr/opt/TruCluster/sys/drd.mod
CHECKSUM: 12207 870
SUBSET: TCRBASE540
[R] UNIX is a registered trademark in the United States and other countries
licensed exclusively through X/Open Company Limited.
Copyright Hewlett-Packard Company 2005. All Rights reserved.
This software is proprietary to and embodies the confidential technology
of Hewlett-Packard Company. Possession, use, or copying of this
software and media is authorized only pursuant to a valid written license
from Hewlett-Packard or an authorized sublicensor.
This ECO has not been through an exhaustive field test process.
Due to the experimental stage of this ECO/workaround, Hewlett-Packard
makes no representations regarding its use or performance. The
customer shall have the sole responsibility for adequate protection
and back-up data used in conjunction with this ECO/workaround.
|