<TITLE>
TITLE: HP Tru64 UNIX - Version 5.1B-3 - Potential System Panic - Simple lock timeout
Copyright (c) Hewlett-Packard Company 2006. All rights reserved.
PRODUCT: HP TruCluster Server [R] V5.1B-2
SOURCE: Hewlett-Packard Company
ECO INFORMATION:
ECO Name: TCRKIT1000455-V51BB25-E-20060317
ECO Kit Approximate Size: 2.77MB
Kit Applies To: HP TruCluster Server V5.1B-2 PK4 (BL25)
ECO Kit CHECKSUMS:
/usr/bin/sum results:
03397 2840
/usr/bin/cksum results:
863427945 2908160
MD5 results:
a271844fb036257ac3ca2acf2f40a819
SHA1 results:
280d1b759a12098b4f70481d11823a765ea99ba2
ECO KIT SUMMARY:
A dupatch-based, Early Release Patch kit exists for HP TruCluster Server V5.1B-2
that contains solutions to the following problem(s):
KCH simple_lock: time limit exceed. A thread after taking simple lock,
returned with out unlocking it.
The Patch Kit Installation Instructions and the Patch Summary and Release
Notes documents provide patch kit installation and removal instructions
and a summary of each patch. Please read these documents prior to
installing patches on your system.
INSTALLATION NOTES:
1) Install this kit with the dupatch utility that is included in the patch
kit. You may need to baseline your system if you have manually changed
system files on your system. The dupatch utility provides the baselining
capability.
2) The patch in this ERP kit does not have any file intersections with any
other ERP available at this time for this product version.
3) This ERP kit will NOT install over any Customer Specific Patches (CSPs)
which have file intersections with this ERP kit. Contact your normal
Service Provider for assistance if the installation of this ERP kit is
blocked by any of your installed CSPs.
INSTALLATION PREREQUISITES:
You must have installed HP TruCluster Server V5.1B-2 PK4 (BL25) prior to
installing this Early Release Patch Kit.
SUPERSEDE INFORMATION:
None
KNOWN PROBLEMS WITH THE PATCH KIT:
None.
RELEASE NOTES FOR TCRKIT1000455-V51BB25-E-20060317:
Release Notes
This document summarizes the contents and special instructions for the
TruCluster Server V5.1B patches contained in this kit.
For information about installing or removing patches, baselining,
and general patch management, see the Patch Kit Installation
Instructions document.
1 Release Notes
This Early Release Patch Kit Distribution contains:
- fixes that resolve the problem(s) reported in:
o 18904
* for TruCluster Server V5.1B T64V51BB25AS0004-20040616.tar (BL25)
This kit includes a patch which requires system reboot.
The patches in this kit are being released early for general customer use.
Refer to the Release Notes for a summary of each patch and installation
prerequisites.
Patches in this kit are installed by running dupatch from the directory
in which the kit was untarred. For example, as root on the target system:
> mkdir -p /tmp/CSPkit1
> cd /tmp/CSPkit1
> <copy the kit to /tmp/CSPkit1>
> tar -xpvf DUV40D13-C0044900-1285-20000328.tar
> cd patch_kit
> ./dupatch
2 Special Instructions
SPECIAL INSTRUCTIONS for TruCluster Server V5.1B Patch C348.00
3 Summary of CSPatches contained in this kit
TruCluster Server V5.1B
PatchId Summary Of Fix
----------------------------------------
C348.00 Solves kch simpelock timeout problem
4 Additional information from Engineering
None
5 Affected system files
This patch delivers the following files:
TruCluster Server V5.1B
Patch C348.00
./usr/opt/TruCluster/sys/kch.mod
CHECKSUM: 28441 430
SUBSET: TCRBASE540
[R] UNIX is a registered trademark in the United States and other countries
licensed exclusively through X/Open Company Limited.
Copyright Hewlett-Packard Company 2006. All Rights reserved.
This software is proprietary to and embodies the confidential technology
of Hewlett-Packard Company. Possession, use, or copying of this
software and media is authorized only pursuant to a valid written license
from Hewlett-Packard or an authorized sublicensor.
This ECO has not been through an exhaustive field test process.
Due to the experimental stage of this ECO/workaround, Hewlett-Packard
makes no representations regarding its use or performance. The
customer shall have the sole responsibility for adequate protection
and back-up data used in conjunction with this ECO/workaround.
|