 |
» |
|
|
 |
 |
 |
|
|
 |
|
<TITLE>
TITLE: HP Tru64 UNIX Version 5.1B-4 - Potential Issue with TruCluster Client
Copyright (c) Hewlett-Packard Company 2007. All rights reserved.
PRODUCT: HP TruCluster Server [R] V5.1B-4
SOURCE: Hewlett-Packard Company
ECO INFORMATION:
ECO Name: TCRKIT1001339-V51BB27-E-20071008
ECO Kit Approximate Size: 5.47MB
Kit Applies To: HP TruCluster Server V5.1B-4 PK6 (BL27)
ECO Kit CHECKSUMS:
/usr/bin/sum results:
45253 5600
/usr/bin/cksum results:
1682618863 5734400
MD5 results:
9210ae964581c0ff7cbad0307866e6a3
SHA1 results:
9fd1c8aacbce7068093ca85faec933393dcac5e1
ECO KIT SUMMARY:
A dupatch-based, Early Release Patch kit exists for HP TruCluster Server V5.1B-4
that contains solutions to the following problem(s):
A potential issue has been reported on HP TruCluster Server software v
5.1B-4. Under certain rare circumstances, a TruCluster client can read
incorrect data.
The Patch Kit Installation Instructions and the Patch Summary and Release
Notes documents provide patch kit installation and removal instructions
and a summary of each patch. Please read these documents prior to
installing patches on your system.
The patches in this ERP kit will also be available in the next mainstream
patch kit - HP TruCluster Server V5.1B-5.
INSTALLATION NOTES:
1) Install this kit with the dupatch utility that is included in the patch
kit. You may need to baseline your system if you have manually changed
system files on your system. The dupatch utility provides the baselining
capability.
2) The patch in this ERP kit does not have any file intersections with any
other ERP available at this time for this product version.
3) This ERP kit will NOT install over any Customer Specific Patches (CSPs)
which have file intersections with this ERP kit. Contact your normal
Service Provider for assistance if the installation of this ERP kit is
blocked by any of your installed CSPs.
INSTALLATION PREREQUISITES:
You must have installed HP TruCluster Server V5.1B-4 PK6 (BL27) prior to
installing this Early Release Patch Kit.
SUPERSEDE INFORMATION:
None
KNOWN PROBLEMS WITH THE PATCH KIT:
None.
RELEASE NOTES FOR TCRKIT1001339-V51BB27-E-20071008:
Release Notes
This document summarizes the contents and special instructions for the
TruCluster Server V5.1B patches contained in this kit.
For information about installing or removing patches, baselining,
and general patch management, see the Patch Kit Installation
Instructions document.
1 Release Notes
This Early Release Patch Kit Distribution contains:
- fixes that resolve the problem(s) reported in:
o 20347 QXCM1000452289
* for TruCluster Server V5.1B T64V51BB27AS0006-20061208.tar (BL27)
This kit includes a patch which requires system reboot.
The patches in this kit are being released early for general customer use.
Refer to the Release Notes for a summary of each patch and installation
prerequisites.
Patches in this kit are installed by running dupatch from the directory
in which the kit was untarred. For example, as root on the target system:
> mkdir -p /tmp/CSPkit1
> cd /tmp/CSPkit1
> <copy the kit to /tmp/CSPkit1>
> tar -xpvf DUV40D13-C0044900-1285-20000328.tar
> cd patch_kit
> ./dupatch
2 Special Instructions
SPECIAL INSTRUCTIONS for TruCluster Server V5.1B Patch C416.00
3 Summary of CSPatches contained in this kit
TruCluster Server V5.1B
PatchId Summary Of Fix
----------------------------------------
C416.00 Fix for data inconsistency seen from CFS client
4 Additional information from Engineering
None
5 Affected system files
This patch delivers the following files:
TruCluster Server V5.1B
Patch C416.00
./usr/opt/TruCluster/sys/cfs.mod
CHECKSUM: 13400 1484
SUBSET: TCRBASE540
[R] UNIX is a registered trademark in the United States and other countries
licensed exclusively through X/Open Company Limited.
Copyright Hewlett-Packard Company 2007. All Rights reserved.
This software is proprietary to and embodies the confidential technology
of Hewlett-Packard Company. Possession, use, or copying of this
software and media is authorized only pursuant to a valid written license
from Hewlett-Packard or an authorized sublicensor.
This ECO has not been through an exhaustive field test process.
Due to the experimental stage of this ECO/workaround, Hewlett-Packard
makes no representations regarding its use or performance. The
customer shall have the sole responsibility for adequate protection
and back-up data used in conjunction with this ECO/workaround.
|